Autoclave
Introduction:
“Classic” make Autoclaves are designed and fabricated for steam
sterilization process to Kill micro-organism through the application of
saturated steam under pressure to suit various I.S. standards
application in the growing field of Medical, Agricultural Institution,
Bio-Chemical Industrial, Research laboratories and Various Industries.
| Features |
a) Steam Temp. 121.4 oC at 15 psi. |
| Specification |
As per BS 2646-5:1993. Autoclaves for sterilization in laboratories Methods of Test for function and performance.
The Energy from the water is transferred into high pressure steam
inside the Stainless steel chamber up to 15-psi pressure or 121.4oC
temperature. The Chamber (electrical) is fill with clean water for
sterilization. This heat process generated chemical free steam for
sterilization. |
| Temp Controller |
Microprocessor based LCD temp. controller ( GMP model optional ) |
| Pressure Controller |
Mechanically operated pressure/steam release valve. |
| Pressure Gauge |
Analog Dial type Pressure Gauge |
| Temperature Sensor |
Standard coupling type PT 100 Sensor ( GMP model) |
| Heat Exchanger |
The electrical heat exchanger transfer latent heat to the clean fill water to generated steam under pressure. |
| Water Level Control |
Low
water level cut off electronic circuit protects the electrical heat
exchanger from low water level inside the chamber, this Cut's off the
power supply to the heat exchanger. |
| Steam Outlet |
Steam
generated from the unit is raised and exits thought the electrically
operated steam Purging solonide valve from the outlet ( GMP model) |
Specification:
| Models |
CS48a |
CS48b |
CS48c |
CS48d |
CS48e |
| Capacity |
35
ltrs |
52
ltrs |
119
ltrs |
178
ltrs |
213
ltrs |
| Inner
Size |
30
dia X 50 h |
35
dia X 55 h |
40
dia X 75 h |
55
dia X 75 h |
55
dia X 90 h |
|
Inner
Chamber |
Stainless
Steel 304 quality |
| External |
Stainless
Steel 304 quality |
| Range |
Ambient
to 15 psi pressure / 121.40C |
| Controller |
Mechanical
Spring loaded value / µ based temp. controller
(GMP) |
| Sensor |
PT
100 (GMP) |
| Accuracy |
+/-0.10C
(GMP) |
| Uniformity |
+/-0.20C
(GMP) |
| Max.
Ramp up time |
45
min. upto 121.40C without load with respect to
ambient (GMP) |
| Insulation |
Air
Bank 50 mm |
| Top
Lid |
With
Dome Shape Die press Stainless Steel Plate |
| Optional |
| Printer
Output |
Printer
output port RS232 |
| Validation
Facility |
Data
logging facility for temperature validation
report. |
| Capacity
(Watts) |
2000 |
3000 |
4000 |
5000 |
6000 |
| Power
Consumption |
10
amps |
15
amps |
20
amps |
25
amps |
30
amps |
| Net
Weight approx. |
15kgs |
20kgs |
30kgs |
50kgs |
55kgs |
|
Electric
requirements AC230 V & 50 Hz cycle. |
|